High Quality Uses of Insulators, High Voltage Insulation Materials, Line Insulators Types Suppliers in China

Home > Products > Composite Insulator > Line Post Composite Insulator > Composite Horizontal Line Post Insulator

Composite Horizontal Line Post Insulator

Basic Info

Model No.: RL-FC

Product Description

Composite Horizontal Line Post Insulator

Post Composite Polymer Insulator 33KV 20KN Line Post Composite Insulator 33KV 11KN Composite Insulator 33kv Line Post Composite Insulator 33KV-10KN Polymer Line Post Insulator


Composite Horizontal Line Post Insulator in Silicone Rubber Type RL FC-*

Dimensions tolerance acc,to IEC61952

Catalogue Code(◆) Specified Cantilever Load kN N°of Sheds A n°(1) Length L ±5 mm Leakage distance mm Dry arc distance mm Power frequency withstand 50Hz Lightning impul. withstand 1,2/50 Weight~kg
Dry Wet posit Negat
KV KV KV KV
FC-* 10 2+1 365 390 165 70 65 115 160 6,5
FC-* 8.4 3+2 420 585 225 110 100 150 190 7,0
FC-* 7.2 4+3 480 780 285 120 110 180 215 7,5
FC-* 6.3 5+4 540 975 340 150 140 235 270 8,0
FC-* 5.5 6+5 600 1170 400 170 155 270 300 8,5
FC-* 5 7+6 660 1365 460 180 165 285 325 9,0
FC-* 4.5 8+7 715 1560 520 200 185 305 355 9,5
FC-* 4.2 9+8 775 1755 575 225 210 345 405 10,0

NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please select the kind of fitting end you have to use and refer to the following table:

Ground fitting Line fitting Code(2) Length
change(L)
Fitting GB Fitting HC HCGB 0
Fitting M Fitting HC HCM 36
Fitting R Fitting HC HCR -78
Fitting GB Fitting B BGB 9
Fitting M Fitting B BM 44
Fitting R Fitting B BR -69
Fitting GB Fitting C CGB -40
Fitting M Fitting C CM -150
Fitting R Fitting C CR -105
Specified Cantilever Load SML-IEC61952
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A4+3-HCGB
Please don`t hesitate to contact us directly for obtaining possible explanations or different solutions.


These insulators are produced and tested according to IEC61952. It`s possible to have all the Other combinations.

RUBBER INSULATOR

Catalogue Code(◆) Specified Cantilever Load kN N°of Sheds A n°(1) Length L ±5 mm Leakage distance mm Dry arc distance mm Power frequency withstand 50Hz Lightning impul. withstand 1,2/50 Weight~kg
Dry Wet

Posit

negat
KV KV KV
KV
FC-* 3,9 10+9 840 1950 635 270 225 450 490 10,5
FC-* 3,3 12+11 955 2340 100% 310 245 515 550 11,5
FC-* 3,0 14+13 1070 2730 870 355 285 570 615 12,5
FC-* 2,7 16+15 1185 3120 985 400 320 625 670 13,5
FC-* 2,4 18+17 1300 3510 1105 435 355 680 735 14,5
FC-* 2,2 20+19 1415 3900 1220 475 390 100% 805 15,5
FC-* 2,0 22+21 1525 4290 1335 520 430 820 890 16,5
FC-* 1,8 24+23 1640 4680 1455 560 475 870 940 17,5

NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please select the kind of fitting end you have to use and refer to the following table:
Ground fitting Line fitting Code(2) Length
change(L)
Fitting GB Fitting HC HCGB 0
Fitting M Fitting HC HCM 36
Fitting R Fitting HC HCR -78
Fitting GB Fitting B BGB 9
Fitting M Fitting B BM 44
Fitting R Fitting B BR -69
Fitting GB Fitting C CGB -40
Fitting M Fitting C CM -150
Fitting R Fitting C CR -105
Specified Cantilever Load SML-IEC61952
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A16+15-HCGB
Please don`t hesitate to contact us directly for obtaining possible explanations or different solutions.
These insulators are produced and tested according to IEC61952. It`s possible to have all the other combinations.

Our Services

1. Small Orders Accepted
2. Fast producing time, Prompt Delivery
3. International Approvals
4. Reply promptly in 24 hours
5. Best Price

FAQ:

1. Q: How about payment terms?
A: 30% TT deposit + 70% TT before shipment,50% TT deposit + 50% LC balance, Flexible payment can be negotiated.
2. Q: Do you have some videos where we can see the line producing?
A: Yes, we can provide some videos for reference.
3. Q: Are you a Manufacture Factory?
A: Yes. We are the direct manufacture factory, and our factory has specialized in porcelain insulator,composite insulator,glass insulator,arrester, Cold And Heat Shrinkable Tube,cut out fuse and power fitting ,etc.

4. Q: How long is producing time ?

A: Normally it will take about 30 days for production.

5. Q: What is the standard of package ?
A: For small capacity, we use carton, but for big capacity, we will use strong wooden case for protection or double inner packs in a master carton.
6. Q: How do you make sure your good quality ?

A: We use the best raw material , and every single product will go through a series of strict test.

insulator

insulation

We warmly welcome friends both domestic and abroad to visit our company, if you have any questions, please contact with us directly.

Contact us if you need more details on Uses of Insulators. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Voltage Insulation Materials、Line Insulators Types. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Composite Insulator > Line Post Composite Insulator