Composite Horizontal Line Post Insulator
Basic Info
Model No.: RL-FC
Product Description
Composite Horizontal Line Post Insulator
Post Composite Polymer Insulator 33KV 20KN Line Post Composite Insulator 33KV 11KN Composite Insulator 33kv Line Post Composite Insulator 33KV-10KN Polymer Line Post Insulator
Composite Horizontal Line Post Insulator in Silicone Rubber Type RL FC-*
Dimensions tolerance acc,to IEC61952
Catalogue Code(◆) | Specified Cantilever Load kN | N°of Sheds A n°(1) | Length L ±5 mm | Leakage distance mm | Dry arc distance mm | Power frequency withstand 50Hz | Lightning impul. withstand 1,2/50 | Weight~kg | ||
Dry | Wet | posit | Negat | |||||||
KV | KV | KV | KV | |||||||
FC-* | 10 | 2+1 | 365 | 390 | 165 | 70 | 65 | 115 | 160 | 6,5 |
FC-* | 8.4 | 3+2 | 420 | 585 | 225 | 110 | 100 | 150 | 190 | 7,0 |
FC-* | 7.2 | 4+3 | 480 | 780 | 285 | 120 | 110 | 180 | 215 | 7,5 |
FC-* | 6.3 | 5+4 | 540 | 975 | 340 | 150 | 140 | 235 | 270 | 8,0 |
FC-* | 5.5 | 6+5 | 600 | 1170 | 400 | 170 | 155 | 270 | 300 | 8,5 |
FC-* | 5 | 7+6 | 660 | 1365 | 460 | 180 | 165 | 285 | 325 | 9,0 |
FC-* | 4.5 | 8+7 | 715 | 1560 | 520 | 200 | 185 | 305 | 355 | 9,5 |
FC-* | 4.2 | 9+8 | 775 | 1755 | 575 | 225 | 210 | 345 | 405 | 10,0 |
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain the total length of the insulator(L),please select the kind of fitting end you have to use and refer to the following table:
Ground fitting | Line fitting | Code(2) | Length |
change(L) | |||
Fitting GB | Fitting HC | HCGB | 0 |
Fitting M | Fitting HC | HCM | 36 |
Fitting R | Fitting HC | HCR | -78 |
Fitting GB | Fitting B | BGB | 9 |
Fitting M | Fitting B | BM | 44 |
Fitting R | Fitting B | BR | -69 |
Fitting GB | Fitting C | CGB | -40 |
Fitting M | Fitting C | CM | -150 |
Fitting R | Fitting C | CR | -105 |
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A4+3-HCGB
Please don`t hesitate to contact us directly for obtaining possible explanations or different solutions.
These insulators are produced and tested according to IEC61952. It`s possible to have all the Other combinations.
Catalogue Code(◆) | Specified Cantilever Load kN | N°of Sheds A n°(1) | Length L ±5 mm | Leakage distance mm | Dry arc distance mm | Power frequency withstand 50Hz | Lightning impul. withstand 1,2/50 | Weight~kg | ||
Dry | Wet | Posit | negat | |||||||
KV | KV | KV | KV | |||||||
FC-* | 3,9 | 10+9 | 840 | 1950 | 635 | 270 | 225 | 450 | 490 | 10,5 |
FC-* | 3,3 | 12+11 | 955 | 2340 | 100% | 310 | 245 | 515 | 550 | 11,5 |
FC-* | 3,0 | 14+13 | 1070 | 2730 | 870 | 355 | 285 | 570 | 615 | 12,5 |
FC-* | 2,7 | 16+15 | 1185 | 3120 | 985 | 400 | 320 | 625 | 670 | 13,5 |
FC-* | 2,4 | 18+17 | 1300 | 3510 | 1105 | 435 | 355 | 680 | 735 | 14,5 |
FC-* | 2,2 | 20+19 | 1415 | 3900 | 1220 | 475 | 390 | 100% | 805 | 15,5 |
FC-* | 2,0 | 22+21 | 1525 | 4290 | 1335 | 520 | 430 | 820 | 890 | 16,5 |
FC-* | 1,8 | 24+23 | 1640 | 4680 | 1455 | 560 | 475 | 870 | 940 | 17,5 |
Ground fitting | Line fitting | Code(2) | Length |
change(L) | |||
Fitting GB | Fitting HC | HCGB | 0 |
Fitting M | Fitting HC | HCM | 36 |
Fitting R | Fitting HC | HCR | -78 |
Fitting GB | Fitting B | BGB | 9 |
Fitting M | Fitting B | BM | 44 |
Fitting R | Fitting B | BR | -69 |
Fitting GB | Fitting C | CGB | -40 |
Fitting M | Fitting C | CM | -150 |
Fitting R | Fitting C | CR | -105 |
Max.Design Cantilever Load MDCL=65%of SCL
Specified Tensile Load(STL) 15kN
Max.design compression 15kN
Max.torsion Load 15daN*m
The SCL can be increased,please contact us.
The metal fittings can be in aluminium or galvanized steel
(◆)Key to the catalogue numbers
*Key:ISI-FC-A(1)-A(2)
Example:ISI-FC-A16+15-HCGB
Please don`t hesitate to contact us directly for obtaining possible explanations or different solutions.
Our Services
1. Small Orders Accepted2. Fast producing time, Prompt Delivery
3. International Approvals
4. Reply promptly in 24 hours
5. Best Price
FAQ:
1. Q: How about payment terms?A: 30% TT deposit + 70% TT before shipment,50% TT deposit + 50% LC balance, Flexible payment can be negotiated.
2. Q: Do you have some videos where we can see the line producing?
A: Yes, we can provide some videos for reference.
3. Q: Are you a Manufacture Factory?
A: Yes. We are the direct manufacture factory, and our factory has specialized in porcelain insulator,composite insulator,glass insulator,arrester, Cold And Heat Shrinkable Tube,cut out fuse and power fitting ,etc.
4. Q: How long is producing time ?
A: Normally it will take about 30 days for production.
5. Q: What is the standard of package ?A: For small capacity, we use carton, but for big capacity, we will use strong wooden case for protection or double inner packs in a master carton.
6. Q: How do you make sure your good quality ?
A: We use the best raw material , and every single product will go through a series of strict test.
We warmly welcome friends both domestic and abroad to visit our company, if you have any questions, please contact with us directly.
Contact us if you need more details on Uses of Insulators. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Voltage Insulation Materials、Line Insulators Types. If these products fail to match your need, please contact us and we would like to provide relevant information.Product Categories : Composite Insulator > Line Post Composite Insulator